Kane KANE455 Manual page 34

Flue gas analyser with direct co2 measurement
Table of Contents

Advertisement

X - AIR :
Excess air calculated from the calculated oxygen. Displays
reading during a combustion test. '-O>-' is displayed while in
fresh air.
CO/CO
:
CO/CO
2
10,000).
PRS:
Pressure reading, either single point or differential
BAT
Displays the Battery power available in %
When the LO BAT symbol appears this indicates the batteries are
at less than 10% of charge and should be replaced, readings may
be affected if used with low power batteries.
DATE :
Date shown as day, month and year, DD/MM/YY. Date is
recorded when each combustion test is printed or stored.
TIME :
The time shown is expressed in "Military" time HH:MM:SS.
Time is recorded when each test is printed or stored.
Note! When changing the batteries on the instrument the
memory will store the date and time for up to one minute, if
outside this time it may be necessary to re-enter the details.
Date and time may also need to be reset if re-chargeable
batteries are allowed to totally discharge.
FULL :
The maximum number of tests have been stored in the memory.
To delete the stored memory, Select Reports then select the tests
to be deleted (see Page 23).
Supplied By www.heating spares.co Tel. 0161 620 6677
Ratio: measured CO (ppm) divided by (CO
2
KANE455 manual
(%) x
2
Page 34