Thermal upgrade kit

Advertisement

The power supply circuitry for the Cisco DSLAM equipment can constitute an energy
Warning
hazard. Before you install or replace the equipment, remove all jewelry (including rings,
necklaces, and watches). Metal objects can come into contact with exposed power
supply wiring or circuitry inside the DSLAM equipment. This could cause the metal
objects to heat up and cause serious burns or weld the metal object to the equipment.
Do not reach into a vacant slot or chassis while you install or remove a module or a fan.
Warning
Exposed circuitry could constitute an energy hazard.
Reseat the Modules
Proper ESD protection is required each time you handle Cisco DSLAM equipment.
Caution
Installation and maintenance personnel should be properly grounded using ground straps
to eliminate the risk of ESD damage to the equipment. Modules are subject to ESD
damage each time they are removed from the chassis.
To reseat all of the modules, complete the following steps. It is important that you accomplish each step
completely before moving on to the next step.
Note
All modules must be fully seated in the chassis. A push on the faceplate of each module
is required for the module to be fully seated.
Step 1
Reseat the xTU-C modules in the Cisco 6100.
a.
b.
c.
d.
Reseat the network interface module in the Cisco 6100.
Step 2
a.
b.
c.
Reseat the POTS modules in the Cisco 6120.
Step 3
a.
b.
c.
d.
78-10158-01
Lift up on the ejector tab and gently apply pressure to the bottom of the faceplate while pushing the
module into the slot.
Push on the faceplate of each module to fully seat the module.
Press down on the ejector tab to secure the module and connect it to the backplane.
Reseat the remaining xTU-C modules using the same procedure.
Lift up on the ejector tabs and gently apply pressure to the bottom of the faceplate while pushing
the module into the slot.
Push on the faceplate of each module to fully seat the module.
Press down on the ejector tabs to secure the module and connect it to the backplane.
Lift up on the ejector tab and gently apply pressure to the bottom of the faceplate while pushing the
module into the slot.
Push on the faceplate of each module to fully seat the module.
Press down on the ejector tab to secure the module and connect it to the backplane.
Reseat the remaining POTS modules using the same procedure.
Installing the Cisco 6100 Thermal Upgrade Kit
Cisco 6100 Thermal Upgrade Kit Installation Procedures
43

Advertisement