Inputs And Outputs; Control Inputs And Outputs (Standard) - Carl Valentin DYNACODE II Service Instructions Manual

Hide thumbs Also See for DYNACODE II:
Table of Contents

Advertisement

Dynacode II
Plug connection - back
side of control unit
Control outputs
Output I
Figure 30, A
Figure 31
05.17

11 Inputs and Outputs

11.1 Control Inputs and Outputs (Standard)

Figure 30
A = Output 1
B = Input 1
C = Output 2
D = External bushing, 15pin (I/O-24)
By means of the signal outputs different operating states of the print
module can be queried.
The signal outputs are provided by two 9-pin SUB-D-bushings
(OUTPUT I and OUTPUT II) on the back side of the control unit.
They consist of optocoupler semiconductor sections, which are
connected through and/or blocked according to different operating
states.
The maximum allowable current in a semiconductor section is
lmax = 30 mA.
PIN (bushing)
Service Instructions
Inputs and Outputs
Port 9-12
Port 1-4
Port 13-16
Port 1 + 9
Output I
Out 1 / Port 9: Error message
Each error status such as ribbon
error is displayed.
Out 2 / Port 10: Print order
The print module was activated by a
print order.
Out 3 / Port 11: Generation
The print module is filled with current
layout data.
Out 4 / Port 12: Layout print
The content of print memory is
transferred on the printable medium
by means of the printhead.
49