Sub card: SC200-GE-T
SC200-GE-T provides a 1000M electrical interface, and the port number can be 25 or 26.
It supports 10/100/1000M auto sensing, it also supports MDI/MDIX switch in auto
negotiation status.
View and explanation of SC200-GE-T:
(1) 10/100/1000M Ethernet electrical interface.
(2) Indicator lights for Ethernet port
(3) Fixing bolt for installation
Light
Color
LNK/ACT
Green
10M
Green
100M
Green
1000M
Green
Sub card: SC200-GE-X
SC200-GE-S1 provides a 1000M optical interface, and the port number can be 25 or 26.
The valid transmission distance is 20km.
View and explanation of SC200-GE-X:
Status
ON
Ethernet port is Link up
Flicking
Ethernet port is transmitting or receiving data
OFF
Ethernet port is Link down
ON
The rate of Ethernet port is 10M
OFF
In Link up status, the rate of Ethernet port is not 10M
ON
The rate of Ethernet port is 100M
OFF
In Link up status, the rate of Ethernet port is not 100M
ON
The rate of Ethernet port is 1000M
OFF
In Link up status, the rate of Ethernet port is not 1000M