Section 7 - Mounting Components In The Vacuum Tube Section - Mod THE PERSUADER Instructions Manual

Table of Contents

Advertisement

3) Cut a 3" piece of wire. Strip ¾" of insulation from one end and tin. Strip ¼" of insulation from the
other end and tin. Connect:
Tube Pins #3 & #8 to Terminal #13
Use the ¾" end to connect both tube pins #3 and #8.
Suggestion: Route the wire along a path to terminal #13 so that its insulation also serves as a spacer between the
terminal strip and the tube socket.
4) Cut a 1" piece of wire and connect:
Tube Pin #4 & Terminal #9
5) Strip and tin a 3 ½" piece of wire and connect:
Tube Pin #5 & Terminal #17
Suggestion: Route the wire along a path to terminal #17 so that its insulation also serves as a spacer between the
terminal strip and the 250K potentiometer.
6) Strip and tin a 1" piece of wire and connect:
Tube Pin #6 & Terminal #14
250KA
7) Strip and tin a 1 ½" piece of wire and connect:
Terminal #15 & 250K pot lug #1
1
3
2
8) Strip and tin a 1 ½" piece of wire and connect:
Terminal #11 & Terminal #13
9) Strip and tin a 1 ¾" piece of wire and connect:
Terminal #12 & Terminal #16
10) Strip and tin a 4" piece of wire and connect:
Terminal #7 & Terminal #10
SECTION 7 – Mounting Components in the Vacuum Tube Section
Please refer to DRAWING 8.
1) Mount the 1K resistor to:
Terminals #5 & #17
2) Mount the 1M resistor to:
Terminals #16 & Tube pin #7 (Do not solder the connection at pin #7, yet.)
3) Mount the 0.1 µF capacitor to:
Tube pin #1 & Tube pin #7 (Now solder the connection at pin #7.)