Maintenance; Lubrication; Checking Hydraulic Oil Level; Replacing Hydraulic Oil - Dake ELEC-DRAULIC I PRESS 5-050 Instructional Manual

Table of Contents

Advertisement

MAINTENANCE

LUBRICATION

• Keep all working parts of the press well-oiled for easier operation.
• Keep a light film of oil over the entire surface of the ram to prevent rust.

CHECKING HYDRAULIC OIL LEVEL

Hydraulic oil should be checked and refilled as needed once a week.
*Amount needed may vary dependent on machine use*
To check, open the weep hole, if oil leaks out then the press is still filled properly. If it is not, use
step 4 in the "SET UP" section of the manual to add oil.

REPLACING HYDRAULIC OIL

Recommended to replace hydraulic oil every 6 months of machine use.
*Amount needed may vary dependent on machine use*
To empty oil, remove the pipe plug located in front of the ram and use a bucket to catch the old
oil. To fill use step 4 in the "SET UP" section of the manual.
Priming the pump is not necessary after replacing oil in the machine.

TROUBLESHOOTING

CAUTION!
• Use extreme caution when disconnecting any parts of the machine to not
introduce any dirt/dust into the hydraulic system, ensure all parts stay clean.
o Filter any oils before adding into the machine.
• When performing any maintenance make sure proper lockout procedure is
followed.
• High pressure fluid is present in operational hydraulic systems. Fluids under high
pressure are dangerous and can cause serious injury or death. Do not make
modifications, repairs or adjustments to a hydraulic system unless you are
competent or working under competent supervision. If in doubt, consult a qualified
technician, engineer, or contact the Dake factory.
905050
11
Dake Corporation
724 Robbins Road
Grand Haven, MI 49417
www.dakecorp.com
REV112019