BASIC SERVICE INFORMATION
NOTICE
For waterproof couplers, never insert the tester leads directly
into the coupler. When performing any checks using a water-
proof coupler, use the specified test harness or a suitable
commercially available test harness.
5. Check:
9 Resistance
Analog pocket tester:
YU-03112-C
Pocket tester:
90890-03112
TIP
The resistance values shown were obtained at the standard meas-
uring temperature of 20 °C (68 °F). If the measuring temperature
is not 20 °C (68 °F), the specified measuring conditions will be
shown.
Intake air temperature sensor
resistance:
5.40–6.60 kW at 0 °C (32 °F)
290–390 W at 80 °C (176 °F)