Operating Guide | VLT® FCD 300 PROFIBUS Converter MCA 117
5.8.4 Conversion of Parameter 803 Time Out After Bus Error
Table 216: Parameter 803
FCD 300 series
Parameter
803 Time Out After Bus Error
Range
1–99
5.8.5 Conversion of Parameter 804 Response After Bus Time Out
Table 217: Parameter 804
FCD 300 series
Parameter
804 Response After Bus Time Out
Options
[0] Off
[1] Freeze Output Frequency
[2] Stop
[3] Jogging
[4] Max Speed
[5] Stop and Trip
[6] No Com. Option Control
[7] Select Set Up 4
5.8.6 Conversion of Parameter 805 Function of Control Word Bit 10
Table 218: Parameter 805
FCD 300 series
Parameter
805 Function of Control Word Bit
Options
[0] No Function
[1] Bit 10 =1
[2] Bit 10 = 0
[3] Bit 10 = 1
5.8.7 Conversion of Parameter 806 SAP Selection (FMS)
Table 219: Parameter 806
Parameter
Danfoss A/S © 2019.11
⇒ CTW active
⇒ CTW active
⇒ Timeout
FCD 300 series
806 SAP Selection (FMS)
FCD 302 series
8-03 Control Word Timeout Time
0.1–18000.0
FCD 302 series
8-04 Control Word Timeout Function
8-02 Control Word Source
[0] Off
[1] Freeze Output Frequency
[2] Stop
[3] Jogging
[4] Max Speed
[5] Stop and Trip
Parameter 8-02 set to RS485
[10] Select Set Up 4
FCD 302 series
8-14 Configurable Control Word CTW
[0] None
[1] Profile Default
[2] CTW Valid, Active Low
[1] CTW Valid, Active High
FCD 302 series
Not converted