Danfoss VLT MCA 117 Operating Manual page 44

Profibus converter vlt decentral drive fcd 302.
Table of Contents

Advertisement

Operating Guide | VLT® FCD 300 PROFIBUS Converter MCA 117
5.3.10 Conversion of Parameter 209 Ramp Up Time 2
Table 71: Parameter 209
Parameter
Range
5.3.11 Conversion of Parameter 210 Ramp Down Time 2
Table 72: Parameter 210
FCD 300 series
Parameter
210 Ramp Down Time 2
Range
0.05–3600.00 s
5.3.12 Conversion of Parameter 211 Jog Ramp Time
Table 73: Parameter 211
Parameter
Range
5.3.13 Conversion of Parameter 212 Quick Stop Ramp Time
Table 74: Parameter 212
FCD 300 series
Parameter
212 Quick Stop Ramp Time
Range
0.05–3600.00 s
5.3.14 Conversion of Parameter 213 Jog Frequency
Table 75: Parameter 213
Parameter
Range
44 | Danfoss A/S © 2019.11
FCD 300 series
209 Ramp Up Time 2
0.05 3600.00 s
FCD 300 series
211 Jog Ramp Time
0.05–3600.00 s
FCD 300 series
213 Jog Frequency
0.0 to parameter 202
FCD 302 series
3-51 Ramp 2 Ramp Up Time
0.01–3600.00 s
FCD 302 series
3-52 Ramp 2 Ramp Down Time
0.01–3600.00 s
FCD 302 series
3-80 Jog Ramp Time
0.01–3600.00 s
FCD 302 series
3-81 Quick Stop Ramp Time
0.01–3600.00 s
FCD 302 series
3-11 Jog Speed [Hz]
0.0 to parameter 4-14
AQ289550754901en-000101 / 130R0890