Danfoss VLT MCA 117 Operating Manual page 52

Profibus converter vlt decentral drive fcd 302.
Table of Contents

Advertisement

Operating Guide | VLT® FCD 300 PROFIBUS Converter MCA 117
FCD 300 series
Options
[0] No Function
[1] Ref min-max = 0–20 mA
[2] Ref min-max = 4–20 mA
[3] FB min-max = 0–20 mA
[4] FB min-max = 4–20 mA
[5] 0–fmax = 0–20 mA
[6] 0–fmax = 4–20 mA
[7] 0–imax = 0–20 mA
[8] 0–imax = 4–20 mA
[9] 0–Pnom = 0–20ámA
[10] 0–Pnom = 4–20 mA
[11] Temp 20–100 C = 0–20 mA
[12] Temp 20–100 C = 4–20 mA
5.4.11 Conversion of Parameter 323 Relay Output
Table 102: Parameter 323
FCD 300 series
Parameter
323 Relay Function
01 Relay
Options
[0] No Function
[1] Control Ready
[2] Ready Signal
[3] Ready - Remote Control
[4] Enabled, No Warning
[5] Running
[6] Running, No Warning
[7] Running Within Range, No Warning
[8] Run At Reference, Nor Warning
[9] Alarm
[10] Alarm Or Warning
52 | Danfoss A/S © 2019.11
Parameter Mapping Lists
FCD 302 series
[0] No Function
[101] Reference
[131] Ref. 4–20 mA
[102] Feedback
[132] Feedback 4–20 mA
[100] Output Frequency
[130] Output Freq. 4–20 mA
[103] Motor Current
[133] Motor Current 4–20 mA
[106] Power
[136] Power 4–20 mA
Not supported
Not supported
FCD 302 series
5-40 Function Relay (Index 0)
Relay 1
Parameter 5-40 = [0] No Operation
Parameter 5-40 = [1] Control Ready
Parameter 5-40 = [2] Drive Ready
Parameter 5-40 = [3] Drive Rdy/Rem Ctrl
Parameter 5-40 = [4] Enable/No Warning
Parameter 5-40 = [5] VLT Running
Parameter 5-40 = [6] Running/No Warning
Parameter 5-40 = [7] Run In Range/No Warn
Parameter 5-40 = [8] Run On Ref/No Warn
Parameter 5-40 = [9] Alarm
Parameter 5-40 = [10] Alarm Or Warning
AQ289550754901en-000101 / 130R0890