Operating Guide | VLT® FCD 300 PROFIBUS Converter MCA 117
5.4.15 Conversion of Parameter 342 Term. 46, Max. Pulse Scaling
Table 106: Parameter 342
FCD 300 series
Parameter
342 Term. 46, Max. Pulse Scaling
Range
150–10000 Hz
5.4.16 Conversion of Parameter 343 Precise Stop Function
Table 107: Parameter 343
FCD 300 series
Parameter
343 Precise Stop Function
Options
[0] Normal
[1] Count Stop Reset
[2] Count Stop No Reset
[3] Spd Cmp Cstop
[4] Spd Cmp Cstop W. Reset
[5] Spd Cmp Cstop No Reset
5.4.17 Conversion of Parameter 344 Counter Value
Table 108: Parameter 344
Parameter
Range
5.4.18 Conversion of Parameter 349 Speed Compensated Delay
Table 109: Parameter 349
FCD 300 series
Parameter
349 Speed Compensated Delay
Range
0–100 ms
Danfoss A/S © 2019.11
FCD 300 series
344 Counter Value
0–999999
FCD 302 series
5-65 Pulse Output Max Freq. #29
0–32000 Hz
FCD 302 series
1-83 Precise Stop Function
[0] Precise Ramp Stop
[1] Cnt Stop With Reset
[2] Cnt Stop W/O Reset
[3] Speed Comp Stop
[4] Cnt Stop W/Rst
[5] Comp Cnt Stop W/O Reset
FCD 302 series
1-84 Precise Stop Counter Value
0–999999999
FCD 302 series
1-85 Precise Stop Speed Compensation Delay
0–100 ms
AQ289550754901en-000101 / 130R0890| 55
Parameter Mapping Lists