5.2.9 Conversion of Parameter 108 Stator Resistor
Table 36: Parameter 108
FCD 300 series
Parameter
108 Stator Resistor
Range
Depending on power unit
5.2.10 Conversion of Parameter 109 Stator Reactance
Table 37: Parameter 109
FCD 300 series
Parameter
109 Stator Reactance
Range
Depending on power unit
5.2.11 Conversion of Parameter 117 Resonance Dampening
Table 38: Parameter 117
FCD 300 series
Parameter
117 Resonance Dampening
Range
0–500%
5.2.12 Conversion of Parameter 119 High Starting Torque
Table 39: Parameter 119
Parameter
5.2.13 Conversion of Parameter 120 Start Delay
Table 40: Parameter 120
Parameter
Range
34 | Danfoss A/S © 2019.11
FCD 300 series
119 High Starting Torque
FCD 300 series
120 Start Delay
0.0–10.0 s
Parameter Mapping Lists
FCD 302 series
1-30 Stator Resistance (Rs)
Depending on power unit
FCD 302 series
1-35 Main Reactance (Xh)
1.0000–10000.0000
FCD 302 series
1-64 Resonance Dampening
0–500%
FCD 302 series
Not converted
FCD 302 series
1-71 Start Delay
0.0–10.0 s