CENTRAL LUBRICATION SYSTEM
LED-DISPLAY
1. Seven-segment display: Values and operating state
2. Pause time (PAUSE h/lmp)
3. Pump operation (CONTACT min/lmp)
4. Monitoring of system function by means of an external
cycle switch (CS)
5. Monitoring of system function by means of an external
pressure switch (PS)
6. Fault message (FAULT)
PUSHBUTTONS
1. Turn on display
Display values and parameters
Set values and parameters
2. Change between programming and display mode
Confirm values (SET)
3. Activatev intermediate lubrication
Clear fault message (DK)
6-64
ATTACHMENTS, OPTIONS
1
2
PAUSE
h/lmp
3
CONTACT
min/lmp
4
CS
5
PS
6
FAULT