MACHINE MONITOR WITH LOAD METER
TOTAL LOAD DATA DISPLAY
1. Check that the normal service meter and time are dis-
played on the character display.
2. Press the ( ) of monitor panel selector switch 1 and dis-
play "LOAD METER".
3. Press the ( ) of monitor panel selector switch 1, then
press the (>) or (<) of monitor panel mode selector switch 2
to display "DATA".
4. Press the ( ) of monitor panel selector switch 1 to display
"TOTAL DATA".
The time when the load on the bottom line was calculated
is displayed as the hour meter standard.
5. Press the (>) or (<) of monitor panel mode selector switch
2 to select the data for each of A to E or the all lighted-up
display.
6-36