4.6
Parameterizing the safety functions integrated in the
drive
Table 4-5: Parameterizing the safety functions integrated in the drive
No.
Action
Now go online with STARTER
1.
again. Download the project and
copy RAM to ROM.
In the project navigator then
change to the "Safety
Integrated" safety functions.
2.
Here, please press the "Change
settings" button.
Please select the extended
safety functions via PROFIsafe.
(Extended functions via
3.
PROFIsafe)
Then enable the safety
functions.
To do this, set the "Safety
functions" to "Enable".
Then press the "Configuration"
4.
button
PROFIsafe SLS Override
Version 1.0, Entry ID: 81682475
4 Configuration and project engineering
Remark
43