Siemens SINAMICS S120 Manual page 51

Entering limit values for safely limited speed (sls) into a sinamics s120 via profisafe with profinet
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

No.
Action
6.
Network 12:
A jump is made to this network
(or to the "SLS" label) if the
condition from network 9 is
fulfilled. Here, the override (AW
19) is set to a value of 32767
(=100%).
Network 13:
A jump is made to the "end"
label from network 11.
As a network may not contain
just one label, the link between
the SSM signal and signal lamp
-L4 was shifted into this network.
The signal lamp (=Q10.7)
contained in pushbutton -S4 is
controlled if the SSM function
signals a HIGH signal.
Network 14:
Pushbutton -S4 is used to
reintegrate the drive.
(acknowledge safety alarms)
FC1
7.
Open the "FC1" function.
In the adjacent screenshot,
safety program (FB1) is
assigned to the FC1 and the
associated I-DB defined.
Select "DB1" as I-DB.
Then acknowledge with "OK".
PROFIsafe SLS Override
Version 1.0, Entry ID: 81682475
4 Configuration and project engineering
Remark
51