Siemens SINAMICS S120 Manual page 48

Entering limit values for safely limited speed (sls) into a sinamics s120 via profisafe with profinet
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

4 Configuration and project engineering
No.
Action
Now insert an additional
2.
function.
This function is called using
what is known as the F call
block with the
safety program. This is simply
created. No changes can be
made in this block.
Please assign the
"FC1" name – and as
programming language, select
"F-CALL".
Click "OK" to confirm what has
been entered.
OB35
3.
Subsequently insert an
organization block.
Assign the "OB35" name, and
select "STL" as programming
language.
Open the OB35 and insert a
network, in which the safety
program is called using the
"CALL FC 1" command.
Then save the block.
48
Remark
PROFIsafe SLS Override
Version 1.0, Entry ID: 81682475