4.2
Mounting the heat pump
CAUTION
Risk of trapping or injury!
The heat pump may tilt if it is not fixed correctly.
▶ Fix the heat pump to the floor.
NOTICE
Risk of Installation problems if installed on sloping surface!
The condensate drainage and functionality will be impaired.
▶ Make sure that the inclination of the heat pump in the horizontal and
vertical direction is no more than 1%.
▶ Use the drill template printed on the accessory carton box to position
the bolts correctly.
▶ Adjust the height using the adjustable feet so that the heat pump
does not tilt.
▶ Secure the heat pump to the ground using suitable screws.
1
2
Fig. 17 Securing the heat pump
[1]
4 pieces M10 X 120 mm (not included)
[2]
Ground brackets
[3]
Flat and strong surface, e.g. concrete plinths
4.3
Installation on floor stand
The heat pump can be mounted on a floor stand if a higher ground
clearence is needed. For information on how to assemble the floor stand
see the accessory manual.
AW 4 | 5 | 7 OR-S – 6721866761 (2023/06)
3
0010039878-002
Fig. 18 Heat pump on floor stand
4.4
Installation with installation kit
The heat pump can be mounted with a pipe and insulation kit both for
ground placement and wall mounted. For information on how to
assemble the kit see the accessory manual.
Fig. 19 Installations kit, ground mounted
Installation
0010044597-001
0010044719-001
11