Hydraulic Depth Stop Tube Assembly - Landoll 6230 Operator's Manual

Disc
Hide thumbs Also See for 6230:
Table of Contents

Advertisement

Hydraulic Depth Stop Tube
Assembly
1. Lay the depth stop tube assembly on top of the
center frame. Insert a 5/8-11 x 3 hex head cap screw
in the rear hole of the tube assembly from the left
side (See Figure 3-5.) Install a 5/8-11 hex nut on the
screw. Do not over tighten, as the depth stop must
pivot on this screw. Insert the screw through the
depth stop mounting plate on the center lift and
secure with a 5/8-11 hex lock nut.
ASSEMBLY INSTRUCTIONS
2. Insert 90 degree elbow fittings in the back and right
side of the limit valve.
3. Using 5/16-18 x 4 hex head cap screws secure the
front end of the depth stop tube assembly to the top
of the frame mount with the spacers, depth stop
plate, and 5/16-18 hex lock nuts. Attach the limit
valve to the bottom side of the center frame mount
using these same screws.
NOTE
It may be necessary to leave these screws loose to
attach the valve hoses later.
3-11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents