Temperature controllers:
➢ Maximum default temperature setting for residential models is 120⁰F
(49⁰C).
• This limit meets the requirements of
various local building codes.
• Enhances the safety of users.
• Temperature settings between 125⁰F and
140⁰F (52⁰ - 60⁰C) are available by setting
DIP switch #6 to the ON position in the
DIPSW1 bank of 8 DIP switches.
NOTE: The RUS/RUCS models do not come
with a temperature controller - temperatures
above 120⁰F are obtained by dip switch
settings.
Commercial C199 models can achieve higher
temperatures utilizing the standard MC-91-2
controller and dip switch settings.