Rinnai RUC80i Training Program page 61

Condensing tankless water heater, level iii, service fundamentals
Table of Contents

Advertisement

Temperature controllers:
98
Fahrenheit F°
37
Celsius C°
* Default maximum temperature is 120⁰F. Temperature settings of 125⁰F to 140⁰F are available by setting switch #6 to the
ON position on DIPSW1 (upper set of switches).
** Temperatures above 140⁰F will require the use of a MCC-91-2 controller on most models
** NOTE: The C199 commercial model does not require the MCC-91-2 controller for temperatures above 140⁰F.
If multiple controllers are connected to one water heater, all controllers will display the same set temperature.
110
Fahrenheit F°
43
Celsius C°
*Alternate temperature settings: Alternate settings are primarily for commercial applications.
To access these alternate settings, dip switches #2 and #3 should be in the ON position on DIPSW2 ( lower set of switches).
NOTE: When alternate temperature settings are used, the minimum temperature setting will be 110⁰F.
NOTE: The maximum set temperature for the RUS/RUCS and RUR98 water heaters is 140⁰F.
NOT allow settings above 140⁰F).
© 2016 Rinnai America Corporation
PROPRIETARY and CONFIDENTIAL
Temperature ranges.
Standard Temperature Setting Range
100
102
104
106
38
39
40
41
Alternate Temperature Setting Range
115
120
125
130
46
49
52
54
Enhancing Lives By Changing The Way Water Is Heated
108
110
115
120
42
43
46
49
135
140
145
150
*
*
57
60
63
66
61
125
130
135
140
*
*
*
*
52
54
57
60
.
155
160
165
170
*
*
*
*
68
71
74
77
(Installing a MCC-91-2 controller will
150
160
185
**
**
**
66
71
85
175
180
185
*
*
*
79
82
85
5/4/2018

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents