Rinnai RUC80i Training Program page 62

Condensing tankless water heater, level iii, service fundamentals
Table of Contents

Advertisement

C199i & C199e:
• The C199 models will come with the MC-91-2
temperature controller (built-in on the C199i
indoor model).
➢ Indoor models will have a default maximum
temperature setting of 140⁰F (DIPSW1, switch
#5 will be OFF and #6 will be ON).
➢ Outdoor models will have a default maximum
temperature setting of 120⁰F WITHOUT the
controller connected (DIPSW1, switch #5 will
be OFF and #6 will be ON).
➢ The temperature can be increased to 140⁰F
WITHOUT the controller by setting #5 to ON
and #6 to OFF.
© 2016 Rinnai America Corporation
PROPRIETARY and CONFIDENTIAL
(temperature options)
Enhancing Lives By Changing The Way Water Is Heated
62