Circulation Pump Removal - RUR Models.
1.
Disconnect the pump power wire harness (black
and white wires).
2.
Remove the six screws securing the pump to the
bottom of the cabinet.
3.
Remove the pump drain (turn counterclockwise).
4.
Lift the pump assembly until the drain fitting
clears the bottom of the cabinet.
5.
Pull the pump forward to remove from the
cabinet.