Benelli TRK 502 Service Station Manual page 77

Hide thumbs Also See for TRK 502:
Table of Contents

Advertisement

the battery cables from the terminals Fig. B
IMPORTANT NOTICE
Disconnect the negative cable of the battery "A" fi rst, and
then the positive cable "B" Fig. B.
Detach:
The battery
Remove the battery rubber tip and slide out the battery "D".
Check:
The battery charge level
Connect a pocket tester to the battery terminals Fig. C.
Check the battery level as shown in the tables of the following
example Fig. D.
NOTE:__________________________________________
The charge status of a battery can be checked by measuring
its open-circuit voltage (that is the voltage when the positive
terminal is disconnected).
If the open-circuit voltage is equal to/above 12.8 V, recharg-
ing is not necessary.
EXAMPLE:
-
Open-circuit voltage = 12.0 V
-
Charging time = 6.5 hours
-
Battery charge amount = 20 -30%
-
Recharge:
The battery (see the fi gure with the suitable charging man-
ner)
IMPORTANT NOTICE
Do not carry out a quick charging of the battery.
WARNING
Never remove the caps that seal the battery.
Do not use fast battery charger as these devices transfer
a high-amperage current to the battery at high speed,
therefore the battery may overheat and its parts may be
damaged.
If it is not possible to adjust the charging current of the bat-
tery charger, be careful to prevent the battery overcharge.
For charging, disconnect the battery from the vehicle.
(Should it be necessary to recharge with the battery mount-
ed on the vehicle, disconnect the negative cable from the
battery terminal).
To reduce the risk of sparks, connect the battery charger to
the power supply only after having connected the cables to
the battery.
ELECTRICAL SYSTEM
BATTERY CHECK AND CHARGING
These values change according to modifi cations of temperature,
battery plates conditions and electrolyte level
A
D
B
13
Relation between the open
circuit voltage and the charge
12.5
time at 20°C
12
11.5
5
6.5
Charge time (hours)
Tempo ricarica (ore)
Questi valori variano col variare della temperatura, della condizione delle piastre della batteria
e del livello di elettrolito.
14
13
12
11
10
100
75
Battery charge status (%)
Stato di ricarica della batteria (%)
B
C
D
Relazione tra la tensione a circuito
aperto e il tempo di ricarica a 20°C
10
E
Room tempe-
Temperatura
rature 20 °C
ambiente 20 °C
50
30 25
0
20
3 - 41