FOR SERVICE TECHNICIAN'S USE ONLY
Service Code
Failure Description
Shown on Display
F-25
Stuck fan on Induction Power
System (IPS) (Right or left side
fan, depending on which side of
the display the failure is on.)
F-36, F-37
Temperature sensor is not
working
Service Code
Failure Description
Shown on Display
F-40
Induction Power System (IPS)
failure
F-42
Power supply
F-43
Under voltage
For Service Technician Use Only
Type of
Repair Suggestions
Failure
1.
Type 2
Unplug range or disconnect power.
2.
Check that the cooling fan connector is firmly plugged in.
3.
Replace all parts and panels before operating.
4.
Plug in range or reconnect power.
5.
If the issue is not fixed, disconnect power.
6.
Replace the cooling fan.
7.
Replace all parts and panels before operating.
8.
Reconnect the power.
9.
If the issue is not fixed, disconnect power.
10. Replace the Induction Power System (IPS).
11. Replace all parts and panels before operating.
12. Plug in range or reconnect power.
1.
Type 1
Unplug range or disconnect power.
2.
Check that the temperature sensor is between 184k and 292k at room temperature
and is firmly plugged in. If the sensor is not between 184k and 292k
and go to Step 5. If the sensor is between 184k and 292k and the electrical connection
is good, go to Step 3.
3.
Replace all parts and panels before operating.
4.
Plug in range or reconnect power and check that the coil is working. If it is not working,
disconnect power and replace the non-working coil and the Induction Power System
(IPS).
5.
Replace all parts and panels before operating.
Type of
Repair Suggestions
6.
Plug in range or reconnect power.
Failure
Type 1 or
1.
Unplug range or disconnect power.
Type 2
2.
Check that the cable between the User Interface and the Induction Power Control (IPC) is
not damaged and is firmly plugged in.
3.
Replace all parts and panels before operating.
4.
Plug in range or reconnect power.
5.
Verify if error is still present. If yes, disconnect power.
6.
Replace the Induction Power System (IPS).
7.
Replace all parts and panels before operating.
8.
Plug in range or reconnect power.
Type 2
1.
Check for 240 volts AC at the main incoming power supply connection by completing the
following steps.
2.
Unplug range or disconnect power.
3.
Connect voltage measurement equipment.
4.
Plug in range or reconnect power and check for 240 volts at J1 L to N, and then J2 L to N
at the EMI filter board, and then J1 L to N at both Induction Power Controls (IPCs). If
voltage is correct, disconnect power, replace the Induction Power System (IPS), and go to
Step 5. If voltage is not correct, disconnect power and check for an open fuse on the EMI
filter board. If there is not an open fuse, have a qualified electrician check the home power
supply.
5.
Replace all parts and panels before operating.
6.
Plug in range or reconnect power.
Type 2
1.
Unplug range or disconnect power.
2.
Check the AC voltage with a multimeter.
3.
Is the voltage above 196 volts? If the AC voltage is below 196 volts, then this failure is
caused by abnormal supply voltage.
4.
If the voltage is above 196 volts, then replace the Induction Power System (IPS).
5.
Replace all parts and panels before operating.
6.
Plug in range or reconnect power.
DIAGNOSTICS & TROUBLESHOOTING
18
19
Vesta Gas and Electric Slide-In Range