Component Testing Chart - Whirlpool IKEA IEL730C Technical Education

Gas and electric slide-in ranges
Hide thumbs Also See for IKEA IEL730C:
Table of Contents

Advertisement

FOR SERVICE TECHNICIAN'S USE ONLY
To check for proper voltage, complete the following steps:
1.
Unplug range or disconnect power.
2.
Connect voltage measurement equipment.
FROM
Door switch
P7-4
Main cavity oven temp
P10-4
sensor
Drawer oven temp sensor
P10-1
Oven light
P5-4
Thermofuse (TOD)
P4-2
FROM
Bake igniter (gas)
P2-3
Broil igniter (gas)
P4-2
Main cavity bake element
P2-3
Broil element
P4-2
Drawer element
P3-1
Convection fan motor
P5-3
Cooktop element (single)
H1
Single, dual, and triple
Term H1(Single
burner elements
only) Term 4, 4A
(double only)
Term 1, 4, 4A
(triple only)
NOTES:
In gas models, the convection fan comes on only after a 5-minute delay in any applicable cooking modes.
In electric models, the convection fan comes on immediately in any applicable cooking modes.
For Service Technician Use Only

Component Testing Chart

TO
RESISTANCE: MEASURE
WITHOUT POWER APPLIED
P7-5
Door open = open circuit
Door closed = closed circuit
P10-3
1000 - 1200 at room temperature.
Measure only resistance, not
voltage.
The operating temperature range is
from -40°F (-40°C) to 1100°F
(593°C).
P10-2
1000 - 1200 at room temperature.
Measure only resistance, not
voltage.
The operating temperature range is
from -40°F (-40°C) to 1100°F
(593°C).
W (Neutral) P6-3 0 - 40 nominal
P6-1
Closed circuit 0 nominal
The switch closed at 170°F ± 11°F
(76 °C ± 6°C) and opens at 280°F
± 8°F (138°C ± 4°C).
Current = 25 Amp
Voltage = 240 Volt
TO
RESISTANCE: MEASURE
W (Neutral) P6-3 40 - 400 nominal at room
WITHOUT POWER APPLIED
temperature.
W (Neutral) P6-3 40 - 400 nominal at room
temperature.
P15-1
10 - 40 nominal.
P15-1
10 - 40 nominal.
W (Neutral) P6-3 10 - 40 nominal.
W (Neutral) P6-3 80 - 95
H2
23-83 nominal
Term 4, 4A
Thermal switch closes/opens at
150°F (66°C) to turn on/off hot
surface indicator light.
Term 2 A
Thermal limiter 0 opens at 1100°F
(593°C).
DIAGNOSTICS & TROUBLESHOOTING
3.
Plug in range or reconnect power and confirm voltage reading.
4.
Unplug range or disconnect power after performing voltage
measurements.
NOTES
Disconnect connector P10 from
control before measuring RTD.
Disconnect connector P10 from
control before measuring RTD.
Hi Limit switch will open if temperature
exceeded.
NOTES
Disconnect bake igniter pigtail
connection
Disconnect broil igniter pigtail
connection
14
For voltage measure in Bake mode;
will cycle between Bake and Broil
elements on when heating.
For voltage, measure in Broil mode.
Only broil element on when heating.
For voltage measure in Bake mode;
will cycle between Bake and Broil
elements on when heating.
Convection fan runs in all convection
cycles and during Bake preheat.
Infinite switch cycles On/Off when hot. 120 VAC
Cooktop On indicator light is on when
any burner is turned on.
15
Vesta Gas and Electric Slide-In Range
NOMINAL
VOLTAGE
5 VDC
NA
NA
120 VAC
240 VAC
NOMINAL
120/240 VAC
VOLTAGE
120 VAC
240 VAC
240 VAC
240 VAC
120 VAC
240 VAC
240 VAC
n