1
EN
IB BP B6 Advanced Connect EN-IN 0920
B6
Preparation
Advanced Connect
1.
2.
3.
4.
5.
6.
Sit on a back-supported chair and keep your legs uncrossed.
Avoid thick or close-fitting garments on the upper arm.
Place the artery-mark on the cuff over your artery.
Fit the cuff closely, but not too tight.
Position the cuff 2-3 cm above your elbow.
Keep your arm still and do not speak during the measurement.

Advertisement

Table of Contents
loading

Summary of Contents for Microlife BP B6 Advanced Connect

  • Page 1 Fit the cuff closely, but not too tight. Position the cuff 2-3 cm above your elbow. Microlife BP B6 Advanced Connect Keep your arm still and do not speak during the measurement. IB BP B6 Advanced Connect EN-IN 0920...
  • Page 2 Microlife BP B6 Advanced Connect Before each measurement Microlife BP B6 Advanced Connect Guarantee Card Microlife BP B6 Advanced Connect Avoid eating, bathing, smoking or caffeine (approx. 30 min). Name of Purchaser Serial Number Date of Purchase Avoid activity and relax for 5-10 min.
  • Page 3 CT Average Indicator «MyCheck» If you have any questions, problems or want to order spare parts please contact your local Microlife-Customer Service. Your dealer or pharmacy will be able to give you the address of the Microlife BP B6 Advanced Connect...
  • Page 4: Table Of Contents

    Alternatively, visit the internet at • Low battery www.microlife.com where you will find a wealth of invaluable infor- • Flat battery – replacement mation on our products. • Which batteries and which procedure? Stay healthy – Microlife ! •...
  • Page 5: What Is Atrial Fibrillation (Af)

    Only use Microlife cuffs. compared to elder people. Contact your local Microlife Service if the enclosed cuff AL does not fit. Connect the cuff to the device by inserting the cuff connector AN Microlife AFIBsens technology provides a convenient way into the cuff socket 6 as far as it will go.
  • Page 6: Checklist For Taking A Reliable Measurement

    3. The cuff will now pump up automatically. Relax, do not move and do not tense your arm muscles until the measurement  To select MAM mode, slide the MAM switch 7 upwards to result is displayed. Breathe normally and do not talk. position <<MAM>>...
  • Page 7: How Do I Evaluate My Blood Pressure

    5. Data Memory How do I evaluate my blood pressure? The LED traffic light indicator on the left-hand side of the display 8 This device automatically stores up to 99 measurement values for indicates within which range the measured blood pressure lies. The each of the 2 users.
  • Page 8: Clearing All Values

    7. Using a Mains Adapter  Cancel deletion: press ON/OFF button 1 while «CL ALL» You can operate this device using the Microlife mains adapter is flashing. (DC 6V, 600 mA).  6. Battery Indicator and Battery change Only use the Microlife mains adapter available as an original accessory appropriate for your supply voltage.
  • Page 9: Error Messages

    10 the measurement result only, always consider other potentially connection seconds. To solve the problem, please occurring symptoms and the patient’s feedback. Calling a doctor visit www.microlife.com/connect. or an ambulance is advised if needed. BP B6 Advanced Connect...
  • Page 10: Device Care

    Protected against solid foreign particles after mechanical impact (e.g. being dropped). Please contact your IP20: with a diameter of more than 12.5 mm, local Microlife-Service to arrange the test (see foreword). no protection against water Disposal ANSI/AAMI/IEC 80601-2-30; Reference to Batteries and electronic devices must be disposed of in ANSI/AAMI/ISO 81060-2;...