Sit on a back-supported chair and keep your legs uncrossed.
Avoid thick or close-fitting garments on the upper arm.
Place the artery-mark on the cuff over your artery.
Fit the cuff closely, but not too tight.
Position the cuff 2-3 cm above your elbow.
Keep your arm still and do not speak during the measurement.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BP B3 Comfort PC and is the answer not in the manual?

Questions and answers

Summary of Contents for Microlife BP B3 Comfort PC

  • Page 1 Fit the cuff closely, but not too tight. Position the cuff 2-3 cm above your elbow. Microlife BP B3 Comfort PC Microlife BP B3 Comfort PC Keep your arm still and do not speak during the measurement. IB BP B3 Comfort PC EN 1119...
  • Page 2 Microlife BP B3 Comfort PC Before each measurement Microlife BP B3 Comfort PC Guarantee Card Microlife BP B3 Comfort PC B3 Comfort Avoid eating, bathing, smoking or caffeine (approx. 30 min). Name of Purchaser Serial Number Date of Purchase Avoid activity and relax for 5-10 min.
  • Page 3 9 Battery Compartment please contact your local Microlife-Customer Service. Your dealer or AT Cuff pharmacy will be able to give you the address of the Microlife dealer AK Cuff Connector in your country. Alternatively, visit the internet at www.microlife.com AL Cuff Tube where you will find a wealth of invaluable information on our products.
  • Page 4: Selecting The Correct Cuff

    Selecting the correct cuff only be displayed after all measurements are taken. Microlife offers different cuff sizes. Select the cuff size to match the  Do not remove the cuff between measurements. circumference of your upper arms (measured by close fitting in the ...
  • Page 5: Taking A Blood Pressure Measurement

    patients first visit in order to determine which arm to measure in  «CL» is displayed when the reading is deleted from the the future. The arm with the higher blood pressure should be memory successfully. measured. How do I evaluate my blood pressure? Remove close-fitting garments from the upper arm.
  • Page 6: Using A Mains Adapter

    6. Using a Mains Adapter be cleared.  Cancel deletion: press ON/OFF button 1 while «CL ALL» You can operate this device using the Microlife mains adapter is flashing. (DC 6V, 600 mA).  Only use the Microlife mains adapter available as an original 5.
  • Page 7: Safety, Care, Accuracy Test And Disposal

     This device comprises sensitive components and must be treated Error Description Potential cause and remedy with caution. Observe the storage and operating conditions «Err 2» Error signal During the measurement, error signals described in the «Technical Specifications» section. were detected by the cuff, caused for AR-B ...
  • Page 8: Technical Specifications

    We recommend this device is tested for accuracy every 2 years or (using new batteries) after mechanical impact (e.g. being dropped). Please contact your IP Class: IP20 local Microlife-Service to arrange the test (see foreword). Reference to EN 1060-1 /-3 /-4; IEC 60601-1; Disposal standards: IEC 60601-1-2 (EMC);...