Password; Alert Tone - Henny Penny GVE-071 Operator's Manual

Split & full vat electric open fryer
Table of Contents

Advertisement

5-3

PASSWORD

5-4

ALERT TONE

(AND VOLUME)
July 2014
The 4-digit passwords can be changed for access to Set-Up, Usage,
Level 1, Level 2, & Get Mgr.)
1.
Press and hold
and
display, followed by ENTER CODE.
2.
Enter code 1, 2, 3, 4 (first 4 product buttons). "PROD" and
"COMP" show in the displays.
3.
Press ▼ button twice and "PASSWORD" shows in the display.
4.
Press right
button and "SET UP" shows in display. The Set up
password can be changed at this time, or press ▼ once to change
the USAGE password, twice for LEVEL 1 password, 3 times for
LEVEL 2 password, or 4 times for GET MGR password. And then,
follow instructions below.
5.
If the password for the Set Up Mode (for example) is to be
changed, press right
shows in the display. Press right
password for the Set Up Mode, using the product buttons
6.
Once new password is entered, "CONFIRM PASSWORD" shows
in the display. Press
another password.
1.
Press and hold
and
the display, followed by "ENTER CODE".
2.
Enter code 1, 2, 3, 4 (first 4 product buttons). "PROD" and
"COMP" show in the displays.
3.
Press ▼ button 3 times and "ALERT TONE" shows in the display.
4.
Press right
button and "VOLUME" shows in the display,
along with the volume value. Use the product buttons
(loudest).
5.
Once volume is set, press
display, along with the tone value. Use the product buttons
6.
Press X to exit Alert Tone Mode.
40
buttons until LEVEL - 2 shows in the
button and "MODIFY? "YES NO"
button to change the 4-digit
.
button to confirm, or press X to choose
buttons until "LEVEL - 2" shows in
to set the volume from 1 (softest) to 10
button and "TONE" shows in
to set the tone from 50 to 2000 Hz.

Hide quick links: