Par.
Configuration
Nr.
options
120
Load factory
setting for service
parameters
201
Machine type
202
Set tank
temperature
203
Pre-rinse time
204
Rinse time
205
Indication of
operation
211
Fine adjustment
Rinse time
218
Lack of rinse aid
219
Lack of detergent
9742146
Use as
Value
range
Parameters
0/1
Parameters
1 - 9
Parameters
10 ... 80
(50 .. 176)
Parameters
0 ... 8
Parameters
4 ... 30
Parameters
0 .. 8
Parameters
0.0..0.9
Parameters
0/1
Parameters
0/1
Unit
-
Effective only upon power supply reset
ON/OFF.
Caution! All changes to service parameters
are reset.
Power supply reset must be carried out within
5 minutes, otherwise factory settings will not
be loaded.
Without the power supply reset, information
123 will be displayed.
-
1: FV 40.2 / FV 60.2 / FV28 GiO-M
2: FV 130.2 / FV 250.2 / DV 270.2
3: DV 80.2 / DV 200.2
4: DV 120.2 / DV 125.2 /
DV 200.2PW
5: FV 70.2D / FV 40.2TL / TopClean60
6: FV 130.2 TL / FV 250.2 TL /
DV 270.2 TL
7: DV 80.2 TL / DV 200.2 TL
8: DV 120.2 TL / DV 125.2 TL /
DV 200.2 TL PW
Caution! Only changes the assignment list
and appliance sequences - not the
parameters
°C/°F
Standard for all the wash programmes of one
device! Output dependent on definition
Sec.
See pre-rinse process step
Sec.
5: FV 40.2/TopClean 60
6: FV 60.2
Energizing duration for the booster pump
(Running time limited by P306!)
-
Definition of the information which triggers the
potential-free contact
0 – no information
1 – filling/heating, ready for washing/washing,
draining
2 – filling/heating, ready for washing/washing
3 – filling/heating
4 – ready for washing
5 – washing
6 – draining
7 – error
8 – not status machine OFF and draining
9 – reserve
10 – not status machine OFF
Sec.
0.7.: FV 40.2/TopClean 60
0.5: FV 60.2
Figures after the decimal point in P204
Monitoring
display
Monitoring
display
30 / 42
Note