15.3.4 Configuration level
You will find a list of configuration parameters at this level (parameter numbers 2xx). You
can view and modify the parameters. You can also access the input and output states or
set outputs for testing.
In the configuration level, first
is shown. This is equivalent to view/modify parameters. (see 15.3.5)
this is equivalent to viewing input status. (see 15.3.6)
this is equivalent to view and set output states. (see 15.3.7)
Press the "I" button to move forwards or the "III" button to move backwards, and the
"accept" button to make a selection. You are now at the current level.
You can leave this level by pressing the "0" button.
15.3.5 Viewing/modifying parameters (depending on the code entered)
Confirm the
display by pressing "Accept".
Now, the first parameter is displayed with a value.
Press the "I" button to go forwards and the "III" button to go backwards, until the
parameter you require is displayed.
Press the "Accept" button to confirm the modification of the parameter; the value flashes.
Press the "I" button to increase the value, the "III" button to decrease the value, and
"accept" to save the value.
You can leave this level by pressing the "0" button.
See 15.4 for a list of parameters.