15.4 Parameter list

Par.
Configuration
Nr.
options
101 Wash programme
Button 1
102 Wash programme
Button 2
103 Wash programme
Button 3
104
Rinse aid
Dosing quantity
105
Detergent
Dosing quantity
106
Degree of
hardness
107
Beep on/off
108
Mode empty
display
109
Partial/full
demineralisation
available?
110
Hardness litres
per cartridge type
111
Total operating
time display
112
Total number of
wash cycles
113
Total number of
wash cycles since
last reset
114
Serial number
115
Condition of
remaining
cartridge capacity
119 IR communication
Use as
Value
range
Parameters
1 .. 50
Parameters
1 .. 50
Parameters
1 .. 50
Parameters
0.10 .. 1.00
Parameters
0.1...20.0
Parameters
0 .. 50
Parameters
0/1
Parameters
0/1
Parameters
0,1,2
Parameters
0 .. 250
Display
5 digits
Display
5 digits
Display
5 digits
Display
8 digits
Display
0 .. 100
Parameters
0/1
Unit
-
Allocate the wash programme to the 1 button;
Assignment adjustable
-
Allocate the wash programme to the 2 button;
Assignment adjustable
-
Allocate the wash programme to the 3 button;
Assignment adjustable
ml/litre
The value can be read from the rinse aid
water
container label (depends on the water quality)
ml/litre
Value can be read from the detergent
water
container label (depends on the water
hardness)
°dH
The quantity of soft water available between
two regenerations depends on the water
hardness
-
Switch acoustic ready message on/off
-
Empty indicator
0: Via INFO 420, 520
1: Output of special characters
-
Partial/full demineralisation available?
0: No
1: Partial demineralisation (PD)
2: Full demineralisation (FD)
1000 L
"Replace cartridge" is displayed when the
cartridge's capacity
is reached (hardness litres/degree of
hardness)
(INFO 725) is displayed (only in the case of
PD)
H
Operating time, query only
-
Wash cycles/loads, query only
-
Wash cycles/loads, resetting possible
-
Option to query factory parameters
%
Only for partial/full demineralisation:
PD: Indication in %
FD: 100 = OK;
0 = Replace
-
It is possible to shut off communication via IR
interfaces. (0)