Hot 'N' Safe Valves available are:
RMC TVA 50HF
RMC TVA 75HFS
Adjustable between 35°C – 55°C
RMC TVA 50HP
For instantaneous gas hot water supply

Inlet Hoses

1. Connect the straight ends of the inlet hoses to the
taps (there are washers fitted in both ends).
Connect the red connector hose to Hot, and the
white connector hose to Cold.
2. Connect the elbow ends of the inlet hoses to the
corresponding machine inlet valves. Inlet valves
are marked on the back of the machine. Ensure
the Hot valve is connected to the hot tap and the
Cold valve is connected to the cold tap.
H = Hot
Cold supply only:
If you only have a cold water supply, an inlet valve cap (blanking cap) MUST be connected to the Hot inlet valve.
The cap prevents water leaking out of the hot valve. The cap is available from your Fisher & Paykel Dealer or
Authorised Repairer, Part No. 388491P. This appliance incorporates backflow protection complying with
AS3500.1. No further backflow protection is required for connection to the water supply.
https://producthelp.fisherpaykel.com/nz/Wash/Top_Loaders/WashSmart/WA1068G1/User_Guide_WA1068G1/02_Installation...
• New hose sets provided
with the washer shall be
used to connect the
washer to the water
mains.
• Old hose sets should not
be re-used.
C = Cold
Fig.3 Inlet hose ends