Water supply

• This clothes washer should be plumbed into both a hot and cold water supply otherwise some cycles may not
function correctly.
Your washer does not have an internal heater to heat water.
• Your hot water should not exceed 65 ̊ C and your cold water should not exceed 35 ̊ C . Temperatures above these
may cause a fault or cause damage to the machine.
• If you have an uncontrolled water-heating source (eg a wet back or solar heating) you should have a tempering
device fitted (eg a safe valve). This will ensure the hot water temperature remains within safe limits. For the most
suitable type of tempering device we recommend you contact a local plumber or plumbing supply merchant.
• Inlet Water Static Pressure of between 34 kPa (5 psi) and 1 MPa (150 psi) is required.
• Minimum flow rate from the tap supplying the clothes washer should be greater than 6 litres / min (assumes 12.7
mm ( inch) diameter pipes).
Hot 'N' Safe Valves available are:
RMC TVA 50HF
RMC TVA 75HFS
Adjustable between 35°C – 55°C
RMC TVA 50HP
For instantaneous gas hot water supply

Inlet hoses

https://producthelp.fisherpaykel.com/nz/Wash/Top_Loaders/CleanSmart/WL1068P1/User_Guide_WL1068P1/02_Installation_...
• New hose sets provided with the washer shall be used to connect the washer to the water
mains.
• Old hose sets should not be re-used.