Troubleshooting And Care; Power Issues - LEGRAND VADDIO AV Bridge 2x1 Installation Manual

Presentation switcher
Table of Contents

Advertisement

Troubleshooting and Care

If the equipment does not power up as expected, use this table to determine whether to call Vaddio
Technical Support.
Note
If the equipment behaves in a way that suggests even a remote possibility of a bad cable, please try a
known good cable with the same pin-out. Factory-made cables can be defective. Cables can appear to be
good but only work part of the time. A cable may pass a standard continuity check but be unable to pass
enough power to the connected device.
Crimping tools can crimp unevenly, contacts can break internally, and individual conductors in the cable
can break inside the jacketing material. Any of these can result in a cable that passes a continuity check
but does not work reliably.
(The author would like to confess having made more than a few almost-good cables. It happens.)

Power Issues

What is it doing?
Nothing. The buttons do not
light up.
Unresponsive camera (no
video, unable to control the
camera, or both)
Installation Guide for the AV Bridge 2x1 Presentation Switcher
Possible causes
Power is not connected.
The wall outlet is not active.
(Check by finding out if it
powers something else, such
as a laptop or phone charger.)
The device or its power injector
is bad.
A cable is connected to the
wrong port.
A cable is bad. (This can even
be a problem with factory
cables.)
There is a problem with the
camera.
Check the connections from the wall
outlet to the PoE+ power injector and
from the power injector to the device.
Use a different outlet.
Contact your reseller or Vaddio
Technical Support.
Check and correct cable connections.
Check using a known good cable with
the same pin-out.
Refer to the troubleshooting information
in the camera manual.
9
Check and correct

Advertisement

Table of Contents
loading

Table of Contents