CLEANING
Clean using a cloth dampened only with water and a little mild detergent.
Use of solvents or hydrocarbon-based cleaners may cause permanent damage.

TROUBLESHOOTING

During Set House ID, the LED is not flashing on some
LightSense™ wireless devices.
If LED is solid green before initiating house ID binding:
The device already has another house ID. Reset it to the factory default
so that it can be bound to the desired house ID. Resetting to factory
defaults is described in the "I need to start over" issue.
If LED is solid yellow after initiating house ID binding:
The device may be out of range of the initiating device. Add a PSWO
LightSense Wireless Repeater to boost signal range.
I made a configuration mistake. I need to start over.
You can reset any Lightsense wireless device to factory default settings
by pressing and holding
(approximately 10 seconds). During the process, the LED flashes yellow
and when complete, it changes to solid yellow. The device can then be
reconfigured, exactly like any new device (see the Set House ID section).
The switch does not work and the status LED is flashing red
at 2Hz (10 times in 5 seconds):
The switch has detected an overload condition and has shut down.
To clear the fault condition, tap
Disconnect loads in excess of rated load and try again.
until the LED changes to solid yellow
and wait for the LED to turn green.