MAINTENANCE

PERIODIC MAINTENANCE
Periodic maintenance should be performed at the following intervals:
Maintenance Operation
Inspect for worn or damaged parts
Check for loose parts
Check engine oil
Thoroughly clean all debris from unit and tine
arms
Oil chains (see lubrication)
Lubricate speed control cables and linkage
Lubricate clutch control cable and linkage
Check Hydraulic oil
Grease front caster assemblies
Inspect belt for wear
Check rear tire pressure
FOR INFORMATION REGARDING SERVICE INTERVALS FOR ENGINE, REFER TO SUPPLIED ENGINE MANUAL
ENGINE MUST BE LEVEL WHEN CHECKING OR FILLING OIL
SERVICING HYDRAULIC SYSTEM
NOTE: DO NOT SERVICE HYDRAULIC SYSTEM WHEN IT IS HOT.
WARNING: Due to the dangerous potential of fluid injection, you should always use a
piece of paper to check for hydraulic leaks rather than using your fingers.
READ all safety instructions before servicing unit.
DISCONNECT spark plug wire before servicing unit.
To check the hydraulic oil level, twist the breather cap on the oil tank counter-clockwise ¼ turn and remove. When
1.
looking inside the filler hole, you should fill the tank so that you can just see oil start to cover the bottom of the internal
strainer. Use 20W-50 engine oil for normal operating temperatures and for colder climates switch to 15W-40. An
excellent choice for colder climates is Mobil 10W-40 Synthetic oil. Over-filling the tank will result in excess oil sloshing
out of the breather during operation.
To change the oil filter it is advisable to clamp the hose from the tank prior to loosening the filter in order to prevent
2.
excessive spilling of hydraulic oil.
Remove filter by un-screwing counter-clockwise from filter base.
3.
When replacing filter (Billy goat P/N 362396), it is recommended to spread a thin coat of oil on the rubber gasket of
4.
the filter prior to re-installing.
After the rubber gasket seats, turn an additional 2/3 turn.
5.
See page 22 for Hydraulic Schematic.
Part No 362500
Every Use
Every 10
(daily)
hrs
8
Every 25 hrs
Every 50 Hours
362500_C_HI

Advertisement

loading

This manual is also suitable for:

Ae1300h