4.10 SKYGUARD OPERATION

SkyGuard provides enhanced control panel protection. When the
SkyGuard sensor is activated, functions in use at the time of actu-
ation will reverse or cutout. The SkyGuard Function Table pro-
vides more details on these functions.
During activation, the horn will sound and, if equipped with a
SkyGuard beacon, the beacon will illuminate until sensor and
footswitch are disengaged.
If the SkyGuard sensor remains activated after function reversal
or cutout, depress and hold the SkyGuard Override Switch to
allow normal functions until the sensor is disengaged.
Consult the following illustrations to determine which type of
SkyGuard the machine has. Regardless of type, SkyGuard func-
tion according to the SkyGuard Function Table does not change.
3121658
SECTION 4 - MACHINE OPERATION

SkyGuard

Approximately 50 lb (222 Nm) of force is applied to yellow bar.

SkyGuard - SkyLine

Cable is pressed, breaking the magnetic connection between the
cable and right bracket.
4-13