Step 4 Set NetEco parameters to ensure that a connection is set up between the SmartLogger1000
and the NetEco 1000S.
Issue 03 (2018-04-11)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
6 System Commissioning
Operation Procedure
5. Choose Auto. Search and press
Before performing the automatic search,
ensure that all the devices can normally
communicate with the SmartLogger1000.
NOTE
After you add, delete, or replace a device, or
change the RS485 address, search for devices
again.
To add a device, search for the device on the
SmartLogger1000 manually or restart the
SmartLogger1000, and then search for the
device again on the network management
system (NetEco 1000S).
After the SmartLogger1000 restarts, the system
automatically searches for devices.
Addr. Allocate allows you to adjust device
addresses based on serial numbers. If a device
cannot access due to address conflict, perform
this operation to assign a new device address
and then access the device.
6. Choose Add Manually and press
NOTE
If the communication is abnormal or the address on
the port has been used, the device cannot be added.
.
.