If any page is blank or a menu cannot be accessed after you log in to the WebUI, clear the
cache, refresh the page, or log in again.
Step 3 Log in as Advanced User. On the Settings tab page, choose Comm. Param. > Ethernet to
set Ethernet parameters.
Figure 6-2 Setting Ethernet parameters
Step 4 Log in as Advanced User. On the Settings tab page, choose Comm. Param. > RS485 to set
RS485 parameters.
Figure 6-3 Setting RS485 parameters
Step 5 Connect the SmartLogger1000 to the SUN2000L.
Issue 03 (2018-04-11)
The SmartLogger1000 IP address must be in the same network segment as the router IP address.
Set Subnet mask to 255.255.255.0.
Set Default gateway to the router IP address.
Set DNS Server Address to the router IP address usually or to an address obtained from the network
carrier.
RS485-1–RS485-3 respectively correspond to communications ports COM1–COM3 on the
SmartLogger1000.
The values of Protocol, Parity, and Baud rate for the devices connecting to the same
communications port must be consistent.