Register Parameter Name
1902 .08
Discharge sensor error
1902 .09
Suction sensor error
I/O CONFIGURATION
ANALOG INPUTS
1005
BPL-1/34
1006
BPH-1/59
1007
Dis. Temp
1008
TempSuction
1009
NC Temp
1010
----------------
1011
----------------
1012
----------------
1013
----------------
1014
----------------
DIGITAL INPUTS
1001.08
Status KL1
1001.09
On/Off
1001.10
General Alarm
1001.11
LiquidAlarm
1001.12
----------------
1001.13
----------------
1001.14
----------------
1001.15
----------------
1001.00
----------------
1001.01
----------------
1001.02
----------------
1001.03
----------------
1001.04
----------------
1001.05
----------------
1001.06
----------------
1001.07
----------------
1002.08
----------------
1002.09
----------------
© Danfoss | DCS (ms) | 2020.01
User
Description
Level
Indicates no signal
from temperature
0
sensor
Indicates no signal
from temperature
0
sensor
Pressure at the R452a
2
suction line
Condensing pressure
2
of R717
Measured discarge
temperature of
2
compressor
Measured suction
2
temperature
Measured non
Condensable gas
2
temperature
Not used
N/A
Not used
N/A
Not used
N/A
Not used
N/A
Not used
N/A
Compressor status
(KL01)
2
0: Compressor off
1: Compressor on
Main switch input
0: Main switch off
2
1: Main switch on
General Alarm input
2
Liquid Alarm input
2
Not used
N/A
Not used
N/A
Not used
N/A
Not used
N/A
Not used
N/A
Not used
N/A
Not used
N/A
Not used
N/A
Not used
N/A
Not used
N/A
Not used
N/A
Not used
N/A
Not used
N/A
Not used
N/A
Default
Min Value
Max Value
Value
0
1
0
0
1
0
-1.0
34.0
N/A
-1.0
59.0
N/A
-50.0
170.0
N/A
-50.0
170.0
N/A
-50.0
170.0
N/A
0
100
N/A
0
100
N/A
0
100
N/A
0
100
N/A
0
100
N/A
0
1
1
0
1
1
0
1
0
0
1
0
0
1
N/A
0
1
N/A
0
1
N/A
0
1
N/A
0
1
N/A
0
1
N/A
0
1
N/A
0
1
N/A
0
1
N/A
0
1
N/A
0
1
N/A
0
1
N/A
0
1
N/A
0
1
N/A
Modbus
Unit/
Read/
Modbus
Function
Type
Write
Data Type
Code
Read
AUTO R.
3
Long
only
Read
AUTO R.
3
Long
only
Read
0-5 V
3
Short
only
Read
0-5 V
3
Short
only
Read
PT1000
3
Short
only
Read
PT1000
3
Short
only
Read
PT1000
3
Short
only
Read
NO
N/A
only
Read
NO
N/A
only
Read
NO
N/A
only
Read
NO
N/A
only
Read
NO
N/A
only
Read
N.O.
3
Short
only
Read
N.O.
3
Short
only
Read
N.O.
3
Short
only
Read
N.O.
3
Short
only
Read
N.C.
N/A
only
Read
N.C.
N/A
only
Read
N.C.
N/A
only
Read
N.C.
N/A
only
Read
N.C.
N/A
only
Read
N.C.
N/A
only
Read
N.C.
N/A
only
Read
N.C.
N/A
only
Read
N.C.
N/A
only
Read
N.C.
N/A
only
Read
N.C.
N/A
only
Read
N.C.
N/A
only
Read
N.C.
N/A
only
Read
N.C.
N/A
only
BC306932151284en-000201 | 25
Persistent
Yes/No
No
No
No
No
No
No
No
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
No
No
No
No
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IPS 8 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

This manual is also suitable for:

084h5001

Table of Contents