Danfoss IPS 8 Technical Data, Installation And Use page 23

Intelligent purging system for ammonia
Hide thumbs Also See for IPS 8:
Table of Contents

Advertisement

User Guide | Intelligent Purging System (IPS 8) for Ammonia - Technical data, installation and use
Register Parameter Name
8116
ValveSetpoint
8117
ValveClose
8119
Event1
8121
Event2
8123
Event3
8125
Event4
8127
Event5
8129
Event6
8131
Event7
8133
PP1
8135
PP2
8137
PP3
8139
PP4
8141
PP5
8143
PP6
8145
PP7
8147
PP8
8149
Val1
8150
Val2
8151
Val3
8152
Val4
8153
Val5
© Danfoss | DCS (ms) | 2020.01
User
Description
Level
Temperature
threshhold for the
0
opening of the main
purge valve
Temperature
threshhold for the
0
closing of the main
purge valve
Purge cycle event -
counts the minutes
that the purge valve
0
has been open on a
finished cycle
Purge cycle event -
counts the accumative
minutes that the
0
purge valve has been
open on a finished
cycle
Purge cycle event -
counts the accumative
minutes that the
0
purge valve has been
open on a finished
cycle
Purge cycle event -
counts the accumative
minutes that the
0
purge valve has been
open on a finished
cycle
Purge cycle event -
counts the accumative
minutes that the
0
purge valve has been
open on a finished
cycle
Purge cycle event -
counts the accumative
minutes that the
0
purge valve has been
open on a finished
cycle
Purge cycle event -
counts the accumative
minutes that the
0
purge valve has been
open on a finished
cycle
The time percentage
0
for this purge point
The time percentage
0
for this purge point
The time percentage
0
for this purge point
The time percentage
0
for this purge point
The time percentage
0
for this purge point
The time percentage
0
for this purge point
The time percentage
0
for this purge point
The time percentage
0
for this purge point
This indicates if the
0
purge point is active
This indicates if the
0
purge point is active
This indicates if the
0
purge point is active
This indicates if the
0
purge point is active
This indicates if the
0
purge point is active
Default
Min Value
Max Value
Value
-2147483648
2147483647
0
-2147483648
2147483647
0
-3276,8
3276,7
0
-3276,8
3276,7
0
-3276,8
3276,7
0
-3276,8
3276,7
0
-3276,8
3276,7
0
-3276,8
3276,7
0
-3276,8
3276,7
0
-32768
32767
0
-32768
32767
0
-32768
32767
0
-32768
32767
0
-32768
32767
0
-32768
32767
0
-32768
32767
0
-32768
32767
0
-32768
32767
0
-32768
32767
0
-32768
32767
0
-32768
32767
0
-32768
32767
0
Modbus
Unit/
Read/
Modbus
Function
Type
Write
Data Type
Code
Read
°C
3
Short
only
Read
°C
3
Long
only
Read
Minutes
3
Long
only
Read
Minutes
3
Long
only
Read
Minutes
3
Long
only
Read
Minutes
3
Long
only
Read
Minutes
3
Long
only
Read
Minutes
3
Long
only
Read
Minutes
3
Long
only
Read
%
3
Long
only
Read
%
3
Long
only
Read
%
3
Long
only
Read
%
3
Long
only
Read
%
3
Long
only
Read
%
3
Long
only
Read
%
3
Long
only
Read
%
3
Long
only
Read
N/A
3
Short
only
Read
N/A
3
Short
only
Read
N/A
3
Short
only
Read
N/A
3
Short
only
Read
N/A
3
Short
only
BC306932151284en-000201 | 23
Persistent
Yes/No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No