5. Cleaning, maintenance and conversion
5−22
Fitting
1. Place the seal (separator plate without channel separ
ation) on the guide sleeves of the left−hand end plate.
Note
Make sure that the separator plate is seated correctly,
see Fig. 5/6.
2. Then place the left−hand end plate on the base block.
3. Tighten the end plate at first by hand, so that the separ
ator plate lies equally on the base block and on the end
plate.
4. Tighten the screws with 3.5 Nm (+0.5 Nm).
Festo P.BE−CDVI−EN en 0702c