Specifications
Input Power
Supply voltage fluctuation
Efficiency
Power Factor
No load input current at 230V
Full load input current at 230V
Output voltage accuracy
Output current accuracy
Voltage Output, DC
Current Output, DC
Constant voltage and current ranges
Constant Voltage characteristics:
Adjustment resolution
Ripple and Noise
Line Regulation (±10%)
Load Regulation (10~90%)
Constant Current characteristics:
Adjustment resolution
Line Regulation (±10%)
Load Regulation (10~90%)
Metering accuracy:
Display
Voltage meter accuracy
Current/watt meter accuracy
User adjustable upper voltage/current limits
Remote Sensing
Protection
Operating %RH
Altitude
Pollution degree
Installation Category
Master/Slave control
Cooling method
Dimensions
Weight
Specifications are subject to change and based on an operating temperature of 25
100 ~ 240VAC (50 to 60Hz), 1.2A
US (NEMA 5-15P to IEC-C13) power cable supplied
Optional EU or UK cables available
± 10% of stated operating voltage
≥ 78%
> 0.9
≤ 150mA
≤ 500mA
± (1.0% reading + 15 digits)
± (1.0% reading + 15 digits)
Auto ranging 36V max. (maximum voltage output at 5A is 16V)
5A max. (maximum current output at 36V is 2.2A)
0.5 ~ 36V / 5A (auto range with 80W max. power)
10mV
≤ 35mVp-p
≤ 4mV
≤ 30mV
10mA
≤ 10mA
≤ 10mA
Dual 4-digit LED
± (0.5% reading + 5 digits)
± (0.5% reading + 5 digits)
Yes
Yes
Over-voltage protection, Current Limiting protection, Short Circuit,
Overload, Over-temperature, Upper voltage limit, Upper Current Limit
10 to 80% RH
2000m
2
CAT II
YES (to max. of 30 units)
Convection
330 x 127 x 53.5mm (13 x 5 x 2") Depth x Height x Width
1.9 kg (4.2lbs.)
8
o
C and Pressure of 0.1Mpa
DCP36-en-GB_V1.1 5/19
Need help?
Do you have a question about the DCP36 and is the answer not in the manual?
Questions and answers