Terminal data

Inverter
Inverter
Connection
Connection type
Max. cable cross-section
Stripping length
Tightening torque
Required tool

Fusing data

EN 60204-1
Inverter
I55AE125B
I55AE125D
I55AE137B
I55AE137D
I55AE155B
I55AE155D
I55AE175B
I55AE175D
I55AE211B
I55AE211D
I55AE215B
I55AE215D
I55AE222B
I55AE222D
kW
0.25 ... 0.75
Mains connection X100
Pluggable screw terminal
mm²
2.5
mm
8
Nm
0.5
0.5 x 3.0
Fuse
Characteristic
gG/gL or gRL
gG/gL or gRL
gG/gL or gRL
gG/gL or gRL
gG/gL or gRL
gG/gL or gRL
gG/gL or gRL
gG/gL or gRL
gG/gL or gRL
gG/gL or gRL
gG/gL or gRL
gG/gL or gRL
gG/gL or gRL
gG/gL or gRL
I55AExxxx
1.1 ... 2.2
6
8
0.7
0.6 x 3.5
Circuit breaker
Max. rated
Characteristic
current
A
10
B
10
B
10
B
10
B
16
B
16
B
16
B
16
B
25
B
25
B
25
B
25
B
25
B
25
B
Electrical installation
Mains connection
1-phase mains connection 230/240 V
0.25 ... 2.2
0.25 ... 2.2
PE connection
Motor connection
PE screw
Pluggable screw
terminal
6
10
2
Torx 20
0.5 x 3.0
Earth-leakage circuit
breaker
Max. rated
current
A
10
≥ 30 mA, type A or B
10
≥ 30 mA, type A or B
10
≥ 30 mA, type A or B
10
≥ 30 mA, type A or B
16
≥ 30 mA, type A or B
16
≥ 30 mA, type A or B
16
≥ 30 mA, type A or B
16
≥ 30 mA, type A or B
25
≥ 30 mA, type A or B
25
≥ 30 mA, type A or B
25
≥ 30 mA, type A or B
25
≥ 30 mA, type A or B
25
≥ 30 mA, type A or B
25
≥ 30 mA, type A or B
X105
2.5
8
0.5