MTS Systems Temposonics R Series Operation Manual page 8

Magnetostrictive linear position sensors, ssi
Hide thumbs Also See for Temposonics R Series:
Table of Contents

Advertisement

Temposonics
R-Series SSI
®
Operation Manual
f
Output
S (14) (15) (16) (17) (18) (19) (20) (21) (22)
= Synchronous Serial Interface
Data length (box no. 14)
1 25 bit
2 24 bit
3 26 bit
Output format (box no. 15)
B Binary
G Gray
Resolution (box no. 16)
1 0.005 mm
2 0.01 mm
3 0.05 mm
4 0.1 mm
5 0.02 mm
6 0.002 mm
8 0.001 mm
9 0.0005 mm
Filtering performance (box no. 17)
A No filter + error delay (4 cycles)
C No filter + error delay (8 cycles)
1 Standard (no filters)
8 Noise reduction filter (8 measurements)
D No filter + error delay (10 cycles)
G Noise reduction filter (8 measurements) + error delay (10 cycles)
K Peak reduction filter (8 measurements)
N Peak reduction filter (8 measurements) + error delay (10 cycles)
Signal options (box no. 18, 19)
0
0 Measuring direction forward, asynchronous mode
1 Measuring direction reverse, asynchronous mode
0
2 Measuring direction forward, synchronous mode 1
0
5 Measuring direction forward, asynchronous mode,
0
bit 25 = alarm, bit 26 = parity even
6 Measuring direction forward, asynchronous mode ,
1
internal linearization
9 Write "9" in box no. 18 and 19 for using further
9
combinations in boxes 20, 21, 22.
6/ You need a second magnet for differentiation measurement
f
Output (continued)
Measurement contents (optional: box no. 20)
Note: Choose "9" in box no. 18 and 19.
1 Position measurement
2 Differentiation measurement
3 Velocity measurement
4 Position measurement + temperature measurement
(only with data length = 24 bit)
5 Differentiation measurement
(only with data length = 24 bit)
6 Velocity measurement + temperature measurement
(only with data length = 24 bit)
Direction and sync. mode (optional: box no. 21)
Note: Choose "9" in box no. 18 and 19.
1 Measuring direction forward, asynchronous mode
2 Measuring direction forward, synchronous mode 1
3 Measuring direction forward, synchronous mode 2
4 Measuring direction forward, synchronous mode 3
5 Measuring direction reverse, asynchronous mode
6 Measuring direction reverse, synchronous mode 1
7 Measuring direction reverse, synchronous mode 2
8 Measuring direction reverse, synchronous mode 3
Internal linearization & diagnostics (optional: box no. 22)
Note: Choose "9" in box no. 18 and 19.
0 No further options
1 Internal linearization
2 Additional alarm bit + parity even bit
(not available for temperature output, only with data length =
24 bit)
4 Additional alarm bit + parity even bit and internal linearization
(not available for temperature output, only with data length =
24 bit)
8
6
+ temperature measurement
6

Hide quick links: