Output (continued)
Filtering performance (box no. 20)
8
Noise reduction filter (8 measurements)
G Noise reduction filter (8 measurements) + error delay (10 cycles)
Signal options (box no. 21, 22)
0
0
Measuring direction forward, asynchronous mode
0
1
Measuring direction reverse, asynchronous mode
0
2
Measuring direction forward, synchronous mode 1
0
Measuring direction forward, asynchronous mode,
5
bit 25 = alarm, bit 26 = parity even
9
9 Write "9" in box no. 21 and 22 for using further
combinations in boxes 23, 24, 25.
Measurement contents (optional: box no. 23)
Note: Choose "9" in box no. 21 and 22.
Position measurement
1
Direction and sync. mode (optional: box no. 24)
Note: Choose "9" in box no. 21 and 22.
Measuring direction forward, asynchronous mode
1
Measuring direction forward, synchronous mode 1
2
Measuring direction reverse, asynchronous mode
5
Measuring direction reverse, synchronous mode 1
6
Diagnostics (optional: box no. 25)
Note: Choose "9" in box no. 21 and 22.
No further options
0
2 Additional alarm bit + parity even bit
12