Side view
(second sensor electronics not shown)
Side view
(second sensor electronics not shown)
Flanges
Threaded flange with flat-face »D« / »M«
51
(2.01)
51
(2.01)
Threaded flange with raised-face »T«
51
(2.01)
51
(2.01)
Controlling design dimensions are in millimeters and measurements in ( ) are in inches
Fig. 25: Temposonics
RT4 flanges with ring magnet
®
NOTICE
Note for installation respectively for replacement
The position measurement is erroneous, if the
sensor will not be connected as shown!
+
I
Ø 18
(Ø 0.7)
Ø 18
(Ø 0.7)
(0.5)
14
(0.5)
14
(0.5)
14
(0.5)
+
II
45 (1.8)
Mounting block
45 (1.8)
Recommendation:
Use M6×45 (ISO 4762) screws for sensor fastening.
Recommendation:
Fastening torque: 6 Nm
Use M6×45 (ISO 4762) screws for sensor fastening.
Fastening torque: 6 Nm
Null zone
57
14
51
Null zone
(2.2)
(2.01)
57
51
A/F 44.5
(2.2)
(2.01)
A/F 44.5
25
(0.98)
71
25
(2.8)
(0.98)
71
(2.8)
Null zone
57
51
Null zone
(2.2)
(2.01)
57
51
(2.2)
(2.01)
A/F 44.5
A/F 44.5
25
(0.98)
25
2.5
(0.98)
(0.10)
71
2.5
(2.8)
(0.10)
71
(2.8)
NOTICE
Mount the sensor as follows:
1. Mount the flange with sensor rod
2. Mount the sensor electronics housing
3. Connect the cable between flange and the sensor electronics
housing
The steps mentioned above will be explained in chapter 4.5.1 and
chapter 4.5.2.
28
Stroke length
Dead zone
25...2540
Stroke length
Dead zone
(1...100)
25...2540
(1...100)
Flange »D«: ¾"-16 UNF-3A
Flange »M«: M18×1.5-6g
Flange »D«: ¾"-16 UNF-3A
Flange »M«: M18×1.5-6g
Stroke length
Dead zone
25...2540
Stroke length
Dead zone
(1...100)
25...2540
(1...100)
Flange »T«: ¾"-16 UNF-3A
Flange »T«: ¾"-16 UNF-3A
64
(2.5)
64
(2.5)
64
(2.5)
64
(2.5)