03 | Keysight | Using an External Trigger to Generate Pulses with the B2960A – Demo Guide
Concept
Figure 1 illustrates the connection diagram and basic setup conditions used in the demo
to make the B2960A series generate pulses whenever it receives an external trigger sig-
nal. Use the settings shown below to program the B2960A source. Connect an oscillo-
scope to the test setup to monitor the results.
B2961A/B2962A
A
-
V
-
Pin 9 (Digital I/O)
Figure 1. Connection diagram and basic condition
Figure 2 shows the parameters used to define the timing parameters of the pulses from
the instrument's front panel. Once these parameters have been specified, the source
value is output immediately after pressing
trigger condition and initiating the channel, the instrument will be ready to receive an
external trigger signal and generate pulsed output.
T
PD
V or I
Pulse
Peak Value
Source Value
Output
T
Off State
Output ON
Figure 2. Timing chart for the pulsed outputs
Figure 3 shows the external trigger signal requirements to initiate device action on the
B2960A series. Positive or negative logic can be used.
V
t
W
5 V
Time
Positive Logic
t
: Trigger Pulse Width > 10 µs
W
Figure 3. External trigger signal requirements
DUT
High Force
Source Mode
Pulse Base (Source value) : 0 V
Pulse Peak
DUT
Pulse Delay
Pulse Width
Count
Low Force
Current Limit
External Trigger Signal
. Next, after configuring an appropriate
: Pulse Delay
T
: Pulse Width
PW
T
T
SP
SP
T
T
T
PD
PW
PD
PW
External Trigger
V
t
W
5 V
Time
Negative Logic
: 1.1 kΩ Resistor
: Voltage
: 2 V
: 300 μs
: 200 μs
: Any or INF.
: 10 mA
T
: Source Trigger Period
SP
T
SP
T
T
PD
PW
Time