IE-CS(T)-2TX-xRS232/485
12
S11
13
S12
TCP alive check time
Setting
0 to 99 min
0 min: The TCP connection will not be closed due to an idle TCP connection.
1 to 99 min: The IE-CS(T)-2TX-xRS232/485 closes the TCP connection automatically if there is no TCP activity
for the given time.
Local TCP port
Setting
1 to 65535
The TCP port that other devices must use to contact this device. To avoid conflicts with standard TCP ports, the
default is set to 4001.

Reverse Telnet Mode

TCP alive check time
Setting
0 to 99 min
0 min: The TCP connection will not be closed due to an idle TCP connection.
1 to 99 min: The IE-CS(T)-2TX-xRS232/485 automatically closes the TCP connection if there is no TCP activity
for the given time.
Inactivity time
Setting
0 to 65535 ms
Idle time setting for auto-disconnection. 0 min. means it will never disconnect.
Local TCP port
Setting
1 to 65535
(always=14, unit 1/10 sec)
DTMF duration and spacing (always=100 ms)
Escape code guard time
(default=50, unit 1/50 sec)
to control the idle time for "+++"
Factory Default
7 min
Factory Default
4001
Factory Default
7 min
Factory Default
0
Factory Default
4001
5-29
Web Console Configuration
no action applied
Necessity
Required
Necessity
Required
Necessity
Optional
Necessity
Optional
Necessity
Required

Advertisement